Installation Services

STANDARD INSTALLATION-SPLIT

Standard ACECORP Back to Back Installation for 15Amp, Wall mounted Split System only includes:

Indoor fan coil mounted on the wall and Outdoor Unit on Same Wall, on the opposite side (externally), At ground level.

Refrigerant piping with insulation, interconnecting cables and fan coil water drainage PVC pipe run vertically, up to 3 meters between the indoor unit and the outdoor unit.

1 x 2.4 meter cream colour bond trunking to cover pipe work (run vertical).

1 x 2.5mm twin and earth Mains power supply, hardwired directly from the Electrical switchboard to the compressor. Distance allowed is up to 15 Meters. Cable run in cavity only.

1 x circuit breaker and single pole enclosure for switchboard.

2 x standard Concrete slabs allowed (400mm x 150mm) for compressor mounting on ground.

Standard install guide only. Each Installation may vary. Materials selected by Acecorp.

Air conditioner excluded. All Acecorp terms and conditions apply. Refer to diagram below.

Below is a diagram of  Acecorp standard installation of a split system.

 

 

STANDARD INSTALLATION-DUCTED

Standard ACECORP  Installation for a Ducted System up to 13Kw only includes:

Indoor unit fan coil mounted on the roof cavity on metal straps.

Outdoor compressor unit mounted at ground level on concrete slabs allowed (400mm x 150mm).

Refrigerant piping with insulation and interconnecting cables pipe run in the cavity, directly between the indoor unit and the outdoor unit, up to 10 meters.

1 x 2.4 meter cream colour bond trunking to cover pipe work (run vertical).

1 x 4mm twin and earth mains power supply, hardwired directly from the Electrical switchboard to the compressor. Distance allowed is up to 15 Meters. Cable run in cavity only.

1 x circuit breaker and single pole enclosure for switchboard.

4 x standard Concrete slabs allowed (400mm x 150mm) for compressor mounting on ground.

Anti Vibration rubber mounted under the outdoor unit.

Up to 6 round 10inch supply air outlets. Up to 8 flexible insulated ducts.

Up to 2 x zone motors. 1 x 2 gang wall mount, zone switch controls.

1 x return air grill with box (900mm x 400mm) and up to 2 ducts.

Up to 4 BTO’s or branch offs. 1 x supply air platinum box and 1 x return air platinum box.

1 x 20mm PVC drainage with ‘p’trap. Up to 8 meters.

Standard install guide only. Each Installation may vary. Materials selected by Acecorp.

Air conditioner excluded. All Acecorp terms and conditions apply. Refer to diagram below.

Below is a diagram of a Acecorp standard installation of a ducted system.